Re: [PATCH net] dt-bindings: net: add support for Microchip KSZ9131 Ethernet PHY

From: Florian Fainelli
Date: Wed Sep 26 2018 - 14:33:48 EST


On 09/26/2018 11:16 AM, Yuiko Oshino wrote:
> Add support for Microchip Technology KSZ9131 10/100/1000 Ethernet phy

Capitalize PHY here.

Targeting the "net" tree which is for bugfixes is not appropriate here
since this is adding support for a new PHY model.

The binding looks reasonable though:

Reviewed-by: Florian Fainelli <f.fainelli@xxxxxxxxx>

>
> Signed-off-by: Yuiko Oshino <yuiko.oshino@xxxxxxxxxxxxx>
> ---
> .../devicetree/bindings/net/micrel-ksz90x1.txt | 29 +++++++++++++++++++++-
> 1 file changed, 28 insertions(+), 1 deletion(-)
>
> diff --git a/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt b/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
> index e22d8cf..d23d14a 100644
> --- a/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
> +++ b/Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
> @@ -1,4 +1,4 @@
> -Micrel KSZ9021/KSZ9031 Gigabit Ethernet PHY
> +Micrel/Microchip KSZ9021/KSZ9031/KSZ9131 Gigabit Ethernet PHY
>
> Some boards require special tuning values, particularly when it comes
> to clock delays. You can specify clock delay values in the PHY OF
> @@ -64,6 +64,33 @@ KSZ9031:
> Attention: The link partner must be configurable as slave otherwise
> no link will be established.
>
> +KSZ9131:
> +
> + All skew control options are specified in picoseconds. The minimum
> + value is 0, and the maximum is property-dependent. The increment
> + step is 100ps. The default value is the neutral setting, so setting
> + rxc-skew-ps=<0> actually results in -700 picoseconds adjustment.
> +
> + Optional properties:
> +
> + Maximum value of 2400, default value 700:
> +
> + - rxc-skew-ps : Skew control of RX clock pad
> + - txc-skew-ps : Skew control of TX clock pad
> +
> + Maximum value of 1500, default value 700:
> +
> + - rxdv-skew-ps : Skew control of RX CTL pad
> + - txen-skew-ps : Skew control of TX CTL pad
> + - rxd0-skew-ps : Skew control of RX data 0 pad
> + - rxd1-skew-ps : Skew control of RX data 1 pad
> + - rxd2-skew-ps : Skew control of RX data 2 pad
> + - rxd3-skew-ps : Skew control of RX data 3 pad
> + - txd0-skew-ps : Skew control of TX data 0 pad
> + - txd1-skew-ps : Skew control of TX data 1 pad
> + - txd2-skew-ps : Skew control of TX data 2 pad
> + - txd3-skew-ps : Skew control of TX data 3 pad
> +
> Examples:
>
> mdio {
>


--
Florian