[PATCH v2 10/17] thermal: rcar_gen3_thermal: enable+check sensor after its setup is finished

From: Bartlomiej Zolnierkiewicz
Date: Wed Oct 17 2018 - 11:54:22 EST


Enable+check sensor after setting tsc->zone and checking ntrips.

Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
---
drivers/thermal/rcar_gen3_thermal.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/thermal/rcar_gen3_thermal.c b/drivers/thermal/rcar_gen3_thermal.c
index c72453e..eb50f33 100644
--- a/drivers/thermal/rcar_gen3_thermal.c
+++ b/drivers/thermal/rcar_gen3_thermal.c
@@ -421,9 +421,6 @@ static int rcar_gen3_thermal_probe(struct platform_device *pdev)
goto error_unregister;
}

- thermal_zone_set_mode(zone, THERMAL_DEVICE_ENABLED);
- thermal_zone_device_check(zone);
-
tsc->zone = zone;

ret = of_thermal_get_ntrips(tsc->zone);
@@ -431,6 +428,9 @@ static int rcar_gen3_thermal_probe(struct platform_device *pdev)
goto error_unregister;

dev_info(dev, "TSC%d: Loaded %d trip points\n", i, ret);
+
+ thermal_zone_set_mode(zone, THERMAL_DEVICE_ENABLED);
+ thermal_zone_device_check(zone);
}

priv->num_tscs = i;
--
1.9.1