[PATCH] thermal: imx: fix for dependency on cpu-freq
From: Anson Huang
Date: Wed Oct 24 2018 - 02:40:02 EST
The thermal driver is a standalone driver for monitoring SoC temperature
by enabling thermal sensor, so it can be enabled even when CONFIG_CPU_FREQ
is NOT set. So remove the dependency with CPU_THERMAL.
Add CONFIG_CPU_FREQ check for cpu-freq related operation in thermal
driver to make thermal driver probe successfully when CONFIG_CPU_FREQ
is NOT set.
Signed-off-by: Anson Huang <Anson.Huang@xxxxxxx>
---
drivers/thermal/Kconfig | 2 +-
drivers/thermal/imx_thermal.c | 4 ++++
2 files changed, 5 insertions(+), 1 deletion(-)
diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig
index 1775d44..c8a6352 100644
--- a/drivers/thermal/Kconfig
+++ b/drivers/thermal/Kconfig
@@ -212,7 +212,7 @@ config HISI_THERMAL
config IMX_THERMAL
tristate "Temperature sensor driver for Freescale i.MX SoCs"
- depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
+ depends on ARCH_MXC || COMPILE_TEST
depends on NVMEM || !NVMEM
depends on MFD_SYSCON
depends on OF
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 1566154..87386d1 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -648,6 +648,7 @@ static const struct of_device_id of_imx_thermal_match[] = {
};
MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
+#ifdef CONFIG_CPU_FREQ
/*
* Create cooling device in case no #cooling-cells property is available in
* CPU node
@@ -668,6 +669,7 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
return 0;
}
+#endif
static int imx_thermal_probe(struct platform_device *pdev)
{
@@ -743,6 +745,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
regmap_write(map, data->socdata->sensor_ctrl + REG_SET,
data->socdata->power_down_mask);
+#ifdef CONFIG_CPU_FREQ
data->policy = cpufreq_cpu_get(0);
if (!data->policy) {
pr_debug("%s: CPUFreq policy not found\n", __func__);
@@ -755,6 +758,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
"failed to register cpufreq cooling device: %d\n", ret);
return ret;
}
+#endif
data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
if (IS_ERR(data->thermal_clk)) {
--
2.7.4