[PATCH AUTOSEL 4.9 52/98] clk: samsung: Fix m2m scaler clock on Exynos542x
From: Sasha Levin
Date: Thu Oct 25 2018 - 10:40:02 EST
From: Andrzej Pietrasiewicz <andrzej.p@xxxxxxxxxxx>
[ Upstream commit c07c1a0f68d0f2f7ca9aff924e2772526027b019 ]
The TOP "aclk400_mscl" clock should be kept enabled all the time
to allow proper access to power management control for MSC power
domain and devices that are a part of it. This change is required
for the scaler to work properly after domain power on/off sequence.
Fixes: 318fa46cc60d ("clk/samsung: exynos542x: mark some clocks as critical")
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@xxxxxxxxxxx>
Signed-off-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@xxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/clk/samsung/clk-exynos5420.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/samsung/clk-exynos5420.c b/drivers/clk/samsung/clk-exynos5420.c
index cdc092a1d9ef..07fb667e258f 100644
--- a/drivers/clk/samsung/clk-exynos5420.c
+++ b/drivers/clk/samsung/clk-exynos5420.c
@@ -987,7 +987,7 @@ static const struct samsung_gate_clock exynos5x_gate_clks[] __initconst = {
GATE(0, "aclk400_isp", "mout_user_aclk400_isp",
GATE_BUS_TOP, 16, 0, 0),
GATE(0, "aclk400_mscl", "mout_user_aclk400_mscl",
- GATE_BUS_TOP, 17, 0, 0),
+ GATE_BUS_TOP, 17, CLK_IS_CRITICAL, 0),
GATE(0, "aclk200_disp1", "mout_user_aclk200_disp1",
GATE_BUS_TOP, 18, CLK_IS_CRITICAL, 0),
GATE(CLK_SCLK_MPHY_IXTAL24, "sclk_mphy_ixtal24", "mphy_refclk_ixtal24",
--
2.17.1