[RFC PATCH v3 09/14] m68k: hp300: Handle timer counter overflow
From: Finn Thain
Date: Fri Nov 23 2018 - 22:12:12 EST
Because hp300_read_clk() never checks the timer interrupt flag it may
fail to notice that the timer has wrapped, allowing the clock to jump
backwards. This is not a new problem.
This is resolved by checking the interrupt flag and, if need be,
taking wrap-around into account. The interrupt handler clears the flag
when it eventually executes.
Signed-off-by: Finn Thain <fthain@xxxxxxxxxxxxxxxxxxx>
---
TODO: find a spare counter for the clocksource, rather than hanging
it off the HZ timer.
---
arch/m68k/hp300/time.c | 44 +++++++++++++++++++++++++-----------------
1 file changed, 26 insertions(+), 18 deletions(-)
diff --git a/arch/m68k/hp300/time.c b/arch/m68k/hp300/time.c
index 90982803a629..ce6b5fc8d4a9 100644
--- a/arch/m68k/hp300/time.c
+++ b/arch/m68k/hp300/time.c
@@ -41,9 +41,12 @@ static u32 clk_total;
#define CLKCR3 CLKCR1
#define CLKSR CLKCR2
#define CLKMSB1 0x5
+#define CLKLSB1 0x7
#define CLKMSB2 0x9
#define CLKMSB3 0xD
+#define CLKSR_INT1 BIT(0)
+
/* This is for machines which generate the exact clock. */
#define HP300_TIMER_CLOCK_FREQ 250000
@@ -70,24 +73,29 @@ static irqreturn_t hp300_tick(int irq, void *dev_id)
static u64 hp300_read_clk(struct clocksource *cs)
{
- unsigned long flags;
- unsigned char lsb, msb1, msb2;
- u32 ticks;
-
- local_irq_save(flags);
- /* Read current timer 1 value */
- msb1 = in_8(CLOCKBASE + 5);
- lsb = in_8(CLOCKBASE + 7);
- msb2 = in_8(CLOCKBASE + 5);
- if (msb1 != msb2)
- /* A carry happened while we were reading. Read it again */
- lsb = in_8(CLOCKBASE + 7);
-
- ticks = INTVAL - ((msb2 << 8) | lsb);
- ticks += clk_total;
- local_irq_restore(flags);
-
- return ticks;
+ unsigned long flags;
+ unsigned char lsb, msb, msb_new;
+ u16 offset = 0;
+ u32 ticks;
+
+ local_irq_save(flags);
+ /* Read current timer 1 value */
+ msb = in_8(CLOCKBASE + CLKMSB1);
+again:
+ if ((in_8(CLOCKBASE + CLKSR) & CLKSR_INT1) && msb > 0)
+ offset = INTVAL;
+ lsb = in_8(CLOCKBASE + CLKLSB1);
+ msb_new = in_8(CLOCKBASE + CLKMSB1);
+ if (msb_new != msb) {
+ msb = msb_new;
+ goto again;
+ }
+
+ ticks = INTVAL - ((msb << 8) | lsb);
+ ticks += offset + clk_total;
+ local_irq_restore(flags);
+
+ return ticks;
}
void __init hp300_sched_init(irq_handler_t vector)
--
2.18.1