Re: [PATCH 03/10] ARM64: dts: fsl: Add all CPUs in cooling maps
From: Shawn Guo
Date: Tue Nov 27 2018 - 21:47:14 EST
On Fri, Nov 16, 2018 at 03:34:26PM +0530, Viresh Kumar wrote:
> Each CPU can (and does) participate in cooling down the system but the
> DT only captures a handful of them, normally CPU0, in the cooling maps.
> Things work by chance currently as under normal circumstances its the
> first CPU of each cluster which is used by the operating systems to
> probe the cooling devices. But as soon as this CPU ordering changes and
> any other CPU is used to bring up the cooling device, we will start
> seeing failures.
>
> Also the DT is rather incomplete when we list only one CPU in the
> cooling maps, as the hardware doesn't have any such limitations.
>
> Update cooling maps to include all devices affected by individual trip
> points.
>
> Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx>
Applied, thanks.