Re: [PATCH V5 1/2] base/drivers/arch_topology: Replace mutex with READ_ONCE / WRITE_ONCE

From: Daniel Lezcano
Date: Thu Nov 29 2018 - 04:18:40 EST


On 29/11/2018 08:04, Juri Lelli wrote:

[ ... ]

>> With or without this patch, it is the case:
>>
>> task1 task2
>> | |
>> read("/sys/.../cpu1/cpu_capacity) |
>> | write("/sys/.../cpu1/cpu_capacity")
>> read("/sys/.../cpu2/cpu_capacity) |
>>
>>
>> There is no guarantee userspace can have a consistent view of the
>> capacity. As soon as it reads a capacity, it can be changed in its back.
>
> True, but w/o the mutex task1 could read different cpu_capacity values
> for a cluster (it actually can also with current implementation, we
> should grab the mutex in the read path as well if we want to avoid
> this).

Even if the mutex is on the read path, the userspace can see different
capacities because it will read the cpu_capacity per cpu directory.

The mutex will be take when reading cpu0/cpu_capacity, not for
cpu[0-9]/cpu_capacity. Between two reads, a write can happen because the
lock is released in between.

Do you agree with the patch ? Or do you want me to drop it ?

--
<http://www.linaro.org/> Linaro.org â Open source software for ARM SoCs

Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog