Re: [PATCH v4 01/20] dt-bindings: mrvl,mmp-timer: add clock

From: Olof Johansson
Date: Fri Nov 30 2018 - 18:56:57 EST


On Wed, Nov 28, 2018 at 06:53:05PM +0100, Lubomir Rintel wrote:
> The timer needs the timer clock to be enabled, otherwise it stops
> ticking.
>
> Signed-off-by: Lubomir Rintel <lkundrak@xxxxx>
> Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
> Acked-by: Pavel Machek <pavel@xxxxxx>
>
> ---
> Changes since v1:
> - Made the clock optional, to keep compatibility with DTs without it

Applied, thanks.


-Olof