[PATCH v2 1/2] serial: 8250: Add dts binding to rate limit serial port during overruns
From: Darwin Dingel
Date: Tue Dec 04 2018 - 19:51:11 EST
When this dts binding is enabled and input overrun on the serial port is
detected, serial port receive will be throttled to give some breathing room
for processing other tasks. This is particularly useful to avoid situations
where serial port HW malfunctions triggering input overruns and then other
processes get starved of processing time. Value provided will be in
milliseconds.
&serial0{
overrun-throttle-ms = <500>;
};
Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
Reviewed-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
Reviewed-by: Jiri Slaby <jslaby@xxxxxxxx>
Signed-off-by: Darwin Dingel <darwin.dingel@xxxxxxxxxxxxxxxxxxx>
---
Documentation/devicetree/bindings/serial/8250.txt | 1 +
1 file changed, 1 insertion(+)
diff --git a/Documentation/devicetree/bindings/serial/8250.txt b/Documentation/devicetree/bindings/serial/8250.txt
index aeb6db4e35c3..da50321da34d 100644
--- a/Documentation/devicetree/bindings/serial/8250.txt
+++ b/Documentation/devicetree/bindings/serial/8250.txt
@@ -51,6 +51,7 @@ Optional properties:
- tx-threshold: Specify the TX FIFO low water indication for parts with
programmable TX FIFO thresholds.
- resets : phandle + reset specifier pairs
+- overrun-throttle-ms : how long to pause uart rx when input overrun is encountered.
Note:
* fsl,ns16550:
--
2.19.2
changes in v2:
- separated dts binding to another patch