[PATCH v2 0/3] add support for Sensirion SPS30 PM sensor
From: Tomasz Duszynski
Date: Thu Dec 06 2018 - 16:05:14 EST
This patch series adds support for Sensirion SPS30 particulate matter
sensor. Along with a driver itself, new channel type and modifiers
for distinguishing between coarse and fine particles measurements are
introduced.
Sensor datasheet can be downloaded from
https://www.sensirion.com/fileadmin/user_upload/customers/sensirion/Dokumente/0_Datasheets/Particulate_Matter/Sensirion_PM_Sensors_SPS30_Datasheet.pdf
v2:
* add support for PM1 and PM4 measurements
* get rid of variable length arrays
* do proper cleanup via devm_add_action_or_reset()
* add extra level of precision (two decimal places) while displaying
measurements
* improve comments a little bit
* slight refactoring and general improvements here and there
Tomasz Duszynski (3):
iio: add IIO_MASSCONCENTRATION channel type
iio: chemical: add support for Sensirion SPS30 sensor
iio: chemical: sps30: add device tree support
Documentation/ABI/testing/sysfs-bus-iio | 17 +-
.../bindings/iio/chemical/sensirion,sps30.txt | 12 +
drivers/iio/chemical/Kconfig | 11 +
drivers/iio/chemical/Makefile | 1 +
drivers/iio/chemical/sps30.c | 406 ++++++++++++++++++
drivers/iio/industrialio-core.c | 5 +
include/uapi/linux/iio/types.h | 5 +
tools/iio/iio_event_monitor.c | 10 +
8 files changed, 466 insertions(+), 1 deletion(-)
create mode 100644 Documentation/devicetree/bindings/iio/chemical/sensirion,sps30.txt
create mode 100644 drivers/iio/chemical/sps30.c
--
2.19.2