Re: [PATCH v1 7/7] arm64: dts: sdm845: wireup the thermal trip points to cpufreq

From: Matthias Kaehlcke
Date: Wed Jan 09 2019 - 21:22:23 EST


Hi Amit,

On Thu, Jan 10, 2019 at 05:30:56AM +0530, Amit Kucheria wrote:
> Since the big and little cpus are in the same frequency domain, use all
> of them for mitigation in the cooling-map. At the lower trip points we
> restrict ourselves to throttling only a few OPPs. At higher trip
> temperatures, allow ourselves to be throttled to any extent.
>
> Signed-off-by: Amit Kucheria <amit.kucheria@xxxxxxxxxx>
> ---
> arch/arm64/boot/dts/qcom/sdm845.dtsi | 145 +++++++++++++++++++++++++++
> 1 file changed, 145 insertions(+)
>
> diff --git a/arch/arm64/boot/dts/qcom/sdm845.dtsi b/arch/arm64/boot/dts/qcom/sdm845.dtsi
> index 29e823b0caf4..cd6402a9aa64 100644
> --- a/arch/arm64/boot/dts/qcom/sdm845.dtsi
> +++ b/arch/arm64/boot/dts/qcom/sdm845.dtsi
> @@ -13,6 +13,7 @@
> #include <dt-bindings/reset/qcom,sdm845-aoss.h>
> #include <dt-bindings/soc/qcom,rpmh-rsc.h>
> #include <dt-bindings/clock/qcom,gcc-sdm845.h>
> +#include <dt-bindings/thermal/thermal.h>
>
> / {
> interrupt-parent = <&intc>;
> @@ -99,6 +100,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x0>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_0>;
> L2_0: l2-cache {
> compatible = "cache";
> @@ -114,6 +116,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x100>;
> enable-method = "psci";
> + #cooling-cells = <2>;

This is not needed (also applies to other for other non-policy
cores). A single cpufreq device is created per frequency domain /
cluster, hence a single cooling device is registered per cluster,
which IMO makes sense given that the CPUs of a cluster can't change
their frequencies independently.

> next-level-cache = <&L2_100>;
> L2_100: l2-cache {
> compatible = "cache";
> @@ -126,6 +129,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x200>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_200>;
> L2_200: l2-cache {
> compatible = "cache";
> @@ -138,6 +142,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x300>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_300>;
> L2_300: l2-cache {
> compatible = "cache";
> @@ -150,6 +155,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x400>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_400>;
> L2_400: l2-cache {
> compatible = "cache";
> @@ -162,6 +168,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x500>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_500>;
> L2_500: l2-cache {
> compatible = "cache";
> @@ -174,6 +181,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x600>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_600>;
> L2_600: l2-cache {
> compatible = "cache";
> @@ -186,6 +194,7 @@
> compatible = "qcom,kryo385";
> reg = <0x0 0x700>;
> enable-method = "psci";
> + #cooling-cells = <2>;
> next-level-cache = <&L2_700>;
> L2_700: l2-cache {
> compatible = "cache";
> @@ -1703,6 +1712,23 @@
> type = "critical";
> };
> };
> +
> + cooling-maps {
> + map0 {
> + trip = <&cpu_alert0>;
> + cooling-device = <&CPU0 THERMAL_NO_LIMIT 4>,
> + <&CPU1 THERMAL_NO_LIMIT 4>,

As per above, there are no cooling devices for CPU1-3 and CPU5-7.

Cheers

Matthias