Hello Scott,
On Fri, Jan 11, 2019 at 01:28:45PM -0800, Scott Branden wrote:
On 2019-01-11 12:48 p.m., Uwe Kleine-KÃnig wrote:IMHO this is no reason to not use the name of the oldest SoC with this
On Fri, Jan 11, 2019 at 10:51:14AM +0530, Sheetal Tigadoli wrote:It doesn't make as much sense here as different revs of the IP block are
From: Praveen Kumar B <praveen.b@xxxxxxxxxxxx>Is v2 used on a newer generation of kona SoCs? On i.MX these variants
Add new compatible string for new version of pwm-kona
Signed-off-by: Praveen Kumar B <praveen.b@xxxxxxxxxxxx>
Reviewed-by: Ray Jui <ray.jui@xxxxxxxxxxxx>
Reviewed-by: Scott Branden <scott.branden@xxxxxxxxxxxx>
Signed-off-by: Sheetal Tigadoli <sheetal.tigadoli@xxxxxxxxxxxx>
---
Documentation/devicetree/bindings/pwm/brcm,kona-pwm.txt | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/pwm/brcm,kona-pwm.txt b/Documentation/devicetree/bindings/pwm/brcm,kona-pwm.txt
index 8eae9fe..d37f697 100644
--- a/Documentation/devicetree/bindings/pwm/brcm,kona-pwm.txt
+++ b/Documentation/devicetree/bindings/pwm/brcm,kona-pwm.txt
@@ -3,7 +3,7 @@ Broadcom Kona PWM controller device tree bindings
This controller has 6 channels.
Required Properties :
-- compatible: should contain "brcm,kona-pwm"
+- compatible: should contain "brcm,kona-pwm" or "brcm,kona-pwm-v2"
are usually named after the first SoC that came with the new variant. Is
this sensible here, too?
picked up based on various decisions.
A new SoC could decide to use an old version.
variant. I don't know how the SoC names are in the broadcom family, but
if they were (in order of age, oldest first):
ant
bear
crocodile
and ant and crocodile use the same IP block we would have
a) with v1, v2:
ant:
compatible = "brcm,kona-pwm-v1";
bear:
compatible = "brcm,kona-pwm-v2";
crocodile:
compatible = "brcm,kona-pwm-v1";
; and
b) with the SoC naming:
ant:
compatible = "brcm,kona-ant-pwm";
bear:
compatible = "brcm,kona-bear-pwm";
crocodile:
compatible = "brcm,kona-crocodile-pwm", "brcm,kona-ant-pwm";
(If you want, drop "brcm,kona-crocodile-pwm", but keeping it is more
defensive.)
I like b) (with "...-crocodile-...") better than a). crocodile using
"...-ant-..." is not more ugly than crocodile using "...-v1". This is
also a tad more robust because if broadcom releases kona-dolphin and
someone finds a minor difference between the IPs used on ant and
crocodile it depends on the order of these events who gets v3, while
with the SoC naming the result is clear.
(OK, and given that "brcm,kona-pwm" is already fixed, both approaches
need slight adaption, but I guess you still get what I meant.)
Cheers,
Best regards
Uwe