Re: [PATCH v4 1/2] pwm: sifive: Add DT documentation for SiFive PWM Controller
From: Yash Shah
Date: Thu Jan 24 2019 - 03:59:25 EST
On Mon, Jan 21, 2019 at 8:29 PM Rob Herring <robh@xxxxxxxxxx> wrote:
>
> On Mon, Jan 21, 2019 at 03:50:42PM +0530, Yash Shah wrote:
> > DT documentation for PWM controller added.
> >
> > Signed-off-by: Wesley W. Terpstra <wesley@xxxxxxxxxx>
> > [Atish: Compatible string update]
> > Signed-off-by: Atish Patra <atish.patra@xxxxxxx>
> > Signed-off-by: Yash Shah <yash.shah@xxxxxxxxxx>
> > ---
> > .../devicetree/bindings/pwm/pwm-sifive.txt | 37 ++++++++++++++++++++++
> > 1 file changed, 37 insertions(+)
> > create mode 100644 Documentation/devicetree/bindings/pwm/pwm-sifive.txt
> >
> > diff --git a/Documentation/devicetree/bindings/pwm/pwm-sifive.txt b/Documentation/devicetree/bindings/pwm/pwm-sifive.txt
> > new file mode 100644
> > index 0000000..b207908
> > --- /dev/null
> > +++ b/Documentation/devicetree/bindings/pwm/pwm-sifive.txt
> > @@ -0,0 +1,37 @@
> > +SiFive PWM controller
> > +
> > +Unlike most other PWM controllers, the SiFive PWM controller currently only
> > +supports one period for all channels in the PWM. This is set globally in DTS.
> > +The period also has significant restrictions on the values it can achieve,
> > +which the driver rounds to the nearest achievable frequency.
> > +
> > +Required properties:
> > +- compatible: Should be "sifive,pwmX" and "sifive,$socname-pwm".
>
> The order here is wrong.
Will fix the order.
>
> You still need to enumeration valid version numbers. Is 'sifive,pwm20'
> valid?
Yes
>
> > + Please refer to sifive-blocks-ip-versioning.txt for details.
> > +- reg: physical base address and length of the controller's registers
> > +- clocks: Should contain a clock identifier for the PWM's parent clock.
> > +- #pwm-cells: Should be 2.
> > + Refer to bindings/pwm/pwm.txt for details.
> > +- sifive,period-ns: the driver will get as close to this period as it can
> > +- interrupts: one interrupt per PWM channel
>
> How many channels? If variable, is the a max number?
Max 4 channels.
>
> > +
> > +PWM RTL that corresponds to the IP block version numbers can be found
> > +here:
> > +
> > +https://github.com/sifive/sifive-blocks/tree/master/src/main/scala/devices/pwm
>
> Put this in the description at the top.
Sure.
>
> > +
> > +Further information on the format of the IP
> > +block-specific version numbers can be found in
> > +Documentation/devicetree/bindings/sifive/sifive-blocks-ip-versioning.txt
>
> You already said this.
Will remove redundant info.
>
> > +
> > +Examples:
> > +
> > +pwm: pwm@10020000 {
> > + compatible = "sifive,fu540-c000-pwm","sifive,pwm0";
>
> Space after the ',' needed.
Sure
>
> > + reg = <0x0 0x10020000 0x0 0x1000>;
> > + clocks = <&tlclk>;
> > + interrupt-parent = <&plic>;
> > + interrupts = <42 43 44 45>;
> > + #pwm-cells = <2>;
> > + sifive,period-ns = <1000000>;
> > +};
> > --
> > 1.9.1
> >
Thanks for the feedback