[PATCH] regulator: mt6311: Use linear instead of linear range for mt6311_buck_ops

From: Axel Lin
Date: Thu Feb 21 2019 - 11:28:31 EST


Current code already set .min_uV and .uV_step fields and it actually can
use regulator_list_voltage_linear.
So remove buck_volt_range and use regulator_list_voltage_linear instead.

Signed-off-by: Axel Lin <axel.lin@xxxxxxxxxx>
Signed-off-by: Mark Brown <broonie@xxxxxxxxxx>
---
drivers/regulator/mt6311-regulator.c | 10 ++--------
1 file changed, 2 insertions(+), 8 deletions(-)

diff --git a/drivers/regulator/mt6311-regulator.c b/drivers/regulator/mt6311-regulator.c
index 0495716fd35f..01d69f43d2b0 100644
--- a/drivers/regulator/mt6311-regulator.c
+++ b/drivers/regulator/mt6311-regulator.c
@@ -38,13 +38,9 @@ static const struct regmap_config mt6311_regmap_config = {
#define MT6311_MAX_UV 1393750
#define MT6311_STEP_UV 6250

-static const struct regulator_linear_range buck_volt_range[] = {
- REGULATOR_LINEAR_RANGE(MT6311_MIN_UV, 0, 0x7f, MT6311_STEP_UV),
-};
-
static const struct regulator_ops mt6311_buck_ops = {
- .list_voltage = regulator_list_voltage_linear_range,
- .map_voltage = regulator_map_voltage_linear_range,
+ .list_voltage = regulator_list_voltage_linear,
+ .map_voltage = regulator_map_voltage_linear,
.set_voltage_sel = regulator_set_voltage_sel_regmap,
.get_voltage_sel = regulator_get_voltage_sel_regmap,
.set_voltage_time_sel = regulator_set_voltage_time_sel,
@@ -71,8 +67,6 @@ static const struct regulator_ops mt6311_ldo_ops = {
.min_uV = MT6311_MIN_UV,\
.uV_step = MT6311_STEP_UV,\
.owner = THIS_MODULE,\
- .linear_ranges = buck_volt_range, \
- .n_linear_ranges = ARRAY_SIZE(buck_volt_range), \
.enable_reg = MT6311_VDVFS11_CON9,\
.enable_mask = MT6311_PMIC_VDVFS11_EN_MASK,\
.vsel_reg = MT6311_VDVFS11_CON12,\
--
2.20.1