Re: [PATCH] net: phy: Micrel KSZ8061: link failure after cable connect
From: Andrew Lunn
Date: Tue Feb 26 2019 - 09:06:20 EST
On Tue, Feb 26, 2019 at 01:45:06PM +0530, Rajasingh Thavamani wrote:
> With Micrel KSZ8061 PHY, the link may occasionally not come up after
> Ethernet cable connect. The vendor's (Microchip, former Micrel) errata
> sheet 80000688A.pdf descripes the problem and possible workarounds in
> detail, see below.
> The batch implements workaround 1, which permanently fixes the issue.
...
> PLAN
> This errata will not be corrected in the future revision.
>
> Signed-off-by: Rajasingh Thavamani <T.Rajasingh@xxxxxxxxxxxxx>
We have been here before:
https://lkml.org/lkml/2018/11/23/466
At that time, the patch was from Alexander Onnasch, and has his
signed-off-by. Now it only has your SOB. It probably should have
both. My reviewed-by has gone missing. And this is version 3? And in
the comments i also included a Fixed: tag, which should be added.
Please submit a v4 with all these issues fixed.
Thanks
Andrew