[PATCH AUTOSEL 4.20 03/60] clk: sunxi: A31: Fix wrong AHB gate number
From: Sasha Levin
Date: Wed Mar 13 2019 - 15:34:30 EST
From: Andre Przywara <andre.przywara@xxxxxxx>
[ Upstream commit ee0b27a3a4da0b0ed2318aa092f8856896e9450b ]
According to the manual the gate clock for MMC3 is at bit 11, and NAND1
is controlled by bit 12.
Fix the gate bit definitions in the clock driver.
Fixes: c6e6c96d8fa6 ("clk: sunxi-ng: Add A31/A31s clocks")
Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx>
Signed-off-by: Maxime Ripard <maxime.ripard@xxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/clk/sunxi-ng/ccu-sun6i-a31.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
diff --git a/drivers/clk/sunxi-ng/ccu-sun6i-a31.c b/drivers/clk/sunxi-ng/ccu-sun6i-a31.c
index 3b97f60540ad..609970c0b666 100644
--- a/drivers/clk/sunxi-ng/ccu-sun6i-a31.c
+++ b/drivers/clk/sunxi-ng/ccu-sun6i-a31.c
@@ -264,9 +264,9 @@ static SUNXI_CCU_GATE(ahb1_mmc1_clk, "ahb1-mmc1", "ahb1",
static SUNXI_CCU_GATE(ahb1_mmc2_clk, "ahb1-mmc2", "ahb1",
0x060, BIT(10), 0);
static SUNXI_CCU_GATE(ahb1_mmc3_clk, "ahb1-mmc3", "ahb1",
- 0x060, BIT(12), 0);
+ 0x060, BIT(11), 0);
static SUNXI_CCU_GATE(ahb1_nand1_clk, "ahb1-nand1", "ahb1",
- 0x060, BIT(13), 0);
+ 0x060, BIT(12), 0);
static SUNXI_CCU_GATE(ahb1_nand0_clk, "ahb1-nand0", "ahb1",
0x060, BIT(13), 0);
static SUNXI_CCU_GATE(ahb1_sdram_clk, "ahb1-sdram", "ahb1",
--
2.19.1