+ Name (_HID, "TITMP75") /* _HID will appear in sysfs */
Sorry for not noticing earlier.
Is this an official ID for the chip? We discourage people to invent ACPI IDs on
their own.
The device is a TI tmp75b temperature sensor [0]. The HID is completely
made up, I'm afraid. It doesn't exist in the registry.
Thanks for clarification. In that case I would rather recommend to use simple
PRP0001 as a _HID.
[0] http://www.ti.com/lit/ds/symlink/tmp75b.pdf