[PATCH] signal: trace_signal_deliver when signal_group_exit

From: Zhenliang Wei
Date: Sat Apr 20 2019 - 06:42:13 EST


In the following commit, removing SIGKILL from each thread signal mask
and executing "goto fatal" directly will skip the call to
"trace_signal_deliver". At this point, the delivery tracking of the SIGKILL
signal will be inaccurate.

commit cf43a757fd4944 ("signal: Restore the stop PTRACE_EVENT_EXIT")

Therefore, we need to add trace_signal_deliver before "goto fatal"
after executing sigdelset.

Signed-off-by: Zhenliang Wei <weizhenliang@xxxxxxxxxx>
---
kernel/signal.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/kernel/signal.c b/kernel/signal.c
index 227ba170298e..439b742e3229 100644
--- a/kernel/signal.c
+++ b/kernel/signal.c
@@ -2441,6 +2441,8 @@ bool get_signal(struct ksignal *ksig)
if (signal_group_exit(signal)) {
ksig->info.si_signo = signr = SIGKILL;
sigdelset(&current->pending.signal, SIGKILL);
+ trace_signal_deliver(signr, &ksig->info,
+ &sighand->action[signr - 1]);
recalc_sigpending();
goto fatal;
}
--
2.14.1.windows.1