[PATCH] platform/x86: pmc_atom: Add Lex 3I380D industrial PC to critclk_systems DMI table

From: Hans de Goede
Date: Mon Apr 29 2019 - 11:01:44 EST


The Lex 3I380D industrial PC has 4 ethernet controllers on board
which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems
DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks
as CLK_CRITICAL and they will not get turned off.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Reported-and-tested-by: Semyon Verchenko <semverchenko@xxxxxxxxxxxx>
Signed-off-by: Hans de Goede <hdegoede@xxxxxxxxxx>
---
drivers/platform/x86/pmc_atom.c | 9 +++++++++
1 file changed, 9 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 3a635ea09b8a..2910845b7cdd 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -407,12 +407,21 @@ static int pmc_dbgfs_register(struct pmc_dev *pmc)
*/
static const struct dmi_system_id critclk_systems[] = {
{
+ /* pmc_plt_clk0 is used for an external HSIC USB HUB */
.ident = "MPL CEC1x",
.matches = {
DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
},
},
+ {
+ /* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
+ .ident = "Lex 3I380D",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
+ DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
+ },
+ },
{ /*sentinel*/ }
};

--
2.21.0