[PATCH] staging: fieldbus: anybus-s: fix wait_for_completion_timeout return handling

From: Sven Van Asbroeck
Date: Wed May 01 2019 - 10:38:31 EST


From: Nicholas Mc Guire <hofrat@xxxxxxxxx>

wait_for_completion_timeout() returns unsigned long (0 on timeout or
remaining jiffies) not int. Assigning this return value to int may
theoretically overflow (though not in this case where TIMEOUT is
only HZ*2).

Fix this inconsistency by wrapping the wait_for_completion_timeout
into the if().

Signed-off-by: Nicholas Mc Guire <hofrat@xxxxxxxxx>
Reviewed-by: Sven Van Asbroeck <TheSven73@xxxxxxxxx>
---
drivers/staging/fieldbus/anybuss/host.c | 5 ++---
1 file changed, 2 insertions(+), 3 deletions(-)

diff --git a/drivers/staging/fieldbus/anybuss/host.c b/drivers/staging/fieldbus/anybuss/host.c
index e34d4249f5a7..a64fe03b61fa 100644
--- a/drivers/staging/fieldbus/anybuss/host.c
+++ b/drivers/staging/fieldbus/anybuss/host.c
@@ -1325,11 +1325,10 @@ anybuss_host_common_probe(struct device *dev,
* interrupt came in: ready to go !
*/
reset_deassert(cd);
- ret = wait_for_completion_timeout(&cd->card_boot, TIMEOUT);
- if (ret == 0)
+ if (!wait_for_completion_timeout(&cd->card_boot, TIMEOUT)) {
ret = -ETIMEDOUT;
- if (ret < 0)
goto err_reset;
+ }
/*
* according to the anybus docs, we're allowed to read these
* without handshaking / reserving the area
--
2.17.1