Quoting Hans de Goede (2019-05-06 08:05:42)
Hi,
On 06-05-19 16:59, Andy Shevchenko wrote:
On Mon, May 6, 2019 at 5:47 PM Hans de Goede <hdegoede@xxxxxxxxxx> wrote:
Hi,
On 06-05-19 14:38, Andy Shevchenko wrote:
On Mon, Apr 29, 2019 at 6:01 PM Hans de Goede <hdegoede@xxxxxxxxxx> wrote:
The Lex 3I380D industrial PC has 4 ethernet controllers on board
which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems
DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks
as CLK_CRITICAL and they will not get turned off.
Acked-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx>
supposedly to go via CLK tree.
P.S. If you want it through PDx86, I need immutable branch / tag from CLK.
Stephen added the patches this depends on to his fixes branch, so they
are in the 5.1 / Torvald's master branch, since we are now in the 5.2 merge
window, you should be able to cleanly apply this directly.
We don't do back merges, so, our base is v5.1-rc1. Does it mean the
commit in question is in v5.1-rc1?
AFAICS it was appeared in v5.1-rc5.
Ah, I see, my bad.
Stephen can you pick up this patch and the
"[PATCH 1/1] Add several Beckhoff Automation boards to critclk_systems DMI table"
patch then?
I guess this is urgent?