Re: [PATCH v4 2/3] PM / EM: Expose perf domain struct
From: Quentin Perret
Date: Wed May 15 2019 - 06:42:37 EST
On Wednesday 15 May 2019 at 15:52:00 (+0530), Viresh Kumar wrote:
> On 15-05-19, 12:16, Daniel Lezcano wrote:
> > Viresh what do you think ?
>
> I agree with your last suggestions. They do make sense.
Good :-)
So, FWIW, the below compiles w/ or w/o THERMAL_GOV_POWER_ALLOCATOR. I'll
test it and clean it up some more and put it as patch 1 in the series if
that's OK.
Thanks,
Quentin
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index f7c1f49ec87f..ee431848ef71 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -58,7 +58,9 @@
*/
struct freq_table {
u32 frequency;
+#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
u32 power;
+#endif
};
/**
@@ -109,28 +111,6 @@ static DEFINE_IDA(cpufreq_ida);
static DEFINE_MUTEX(cooling_list_lock);
static LIST_HEAD(cpufreq_cdev_list);
-/* Below code defines functions to be used for cpufreq as cooling device */
-
-/**
- * get_level: Find the level for a particular frequency
- * @cpufreq_cdev: cpufreq_cdev for which the property is required
- * @freq: Frequency
- *
- * Return: level corresponding to the frequency.
- */
-static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
- unsigned int freq)
-{
- struct freq_table *freq_table = cpufreq_cdev->freq_table;
- unsigned long level;
-
- for (level = 1; level <= cpufreq_cdev->max_level; level++)
- if (freq > freq_table[level].frequency)
- break;
-
- return level - 1;
-}
-
/**
* cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
* @nb: struct notifier_block * with callback info.
@@ -184,6 +164,27 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb,
return NOTIFY_OK;
}
+#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
+/**
+ * get_level: Find the level for a particular frequency
+ * @cpufreq_cdev: cpufreq_cdev for which the property is required
+ * @freq: Frequency
+ *
+ * Return: level corresponding to the frequency.
+ */
+static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev,
+ unsigned int freq)
+{
+ struct freq_table *freq_table = cpufreq_cdev->freq_table;
+ unsigned long level;
+
+ for (level = 1; level <= cpufreq_cdev->max_level; level++)
+ if (freq > freq_table[level].frequency)
+ break;
+
+ return level - 1;
+}
+
/**
* update_freq_table() - Update the freq table with power numbers
* @cpufreq_cdev: the cpufreq cooling device in which to update the table
@@ -333,80 +334,6 @@ static u32 get_dynamic_power(struct cpufreq_cooling_device *cpufreq_cdev,
return (raw_cpu_power * cpufreq_cdev->last_load) / 100;
}
-/* cpufreq cooling device callback functions are defined below */
-
-/**
- * cpufreq_get_max_state - callback function to get the max cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: fill this variable with the max cooling state.
- *
- * Callback for the thermal cooling device to return the cpufreq
- * max cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
-static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
- unsigned long *state)
-{
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
-
- *state = cpufreq_cdev->max_level;
- return 0;
-}
-
-/**
- * cpufreq_get_cur_state - callback function to get the current cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: fill this variable with the current cooling state.
- *
- * Callback for the thermal cooling device to return the cpufreq
- * current cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
-static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
- unsigned long *state)
-{
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
-
- *state = cpufreq_cdev->cpufreq_state;
-
- return 0;
-}
-
-/**
- * cpufreq_set_cur_state - callback function to set the current cooling state.
- * @cdev: thermal cooling device pointer.
- * @state: set this variable to the current cooling state.
- *
- * Callback for the thermal cooling device to change the cpufreq
- * current cooling state.
- *
- * Return: 0 on success, an error code otherwise.
- */
-static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
- unsigned long state)
-{
- struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
- unsigned int clip_freq;
-
- /* Request state should be less than max_level */
- if (WARN_ON(state > cpufreq_cdev->max_level))
- return -EINVAL;
-
- /* Check if the old cooling action is same as new cooling action */
- if (cpufreq_cdev->cpufreq_state == state)
- return 0;
-
- clip_freq = cpufreq_cdev->freq_table[state].frequency;
- cpufreq_cdev->cpufreq_state = state;
- cpufreq_cdev->clipped_freq = clip_freq;
-
- cpufreq_update_policy(cpufreq_cdev->policy->cpu);
-
- return 0;
-}
-
/**
* cpufreq_get_requested_power() - get the current power
* @cdev: &thermal_cooling_device pointer
@@ -551,22 +478,93 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
power);
return 0;
}
+#endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */
+
+/* cpufreq cooling device callback functions are defined below */
+
+/**
+ * cpufreq_get_max_state - callback function to get the max cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: fill this variable with the max cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * max cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
+ unsigned long *state)
+{
+ struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
+
+ *state = cpufreq_cdev->max_level;
+ return 0;
+}
+
+/**
+ * cpufreq_get_cur_state - callback function to get the current cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: fill this variable with the current cooling state.
+ *
+ * Callback for the thermal cooling device to return the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
+ unsigned long *state)
+{
+ struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
+
+ *state = cpufreq_cdev->cpufreq_state;
+
+ return 0;
+}
+
+/**
+ * cpufreq_set_cur_state - callback function to set the current cooling state.
+ * @cdev: thermal cooling device pointer.
+ * @state: set this variable to the current cooling state.
+ *
+ * Callback for the thermal cooling device to change the cpufreq
+ * current cooling state.
+ *
+ * Return: 0 on success, an error code otherwise.
+ */
+static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
+ unsigned long state)
+{
+ struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata;
+ unsigned int clip_freq;
+
+ /* Request state should be less than max_level */
+ if (WARN_ON(state > cpufreq_cdev->max_level))
+ return -EINVAL;
+
+ /* Check if the old cooling action is same as new cooling action */
+ if (cpufreq_cdev->cpufreq_state == state)
+ return 0;
+
+ clip_freq = cpufreq_cdev->freq_table[state].frequency;
+ cpufreq_cdev->cpufreq_state = state;
+ cpufreq_cdev->clipped_freq = clip_freq;
+
+ cpufreq_update_policy(cpufreq_cdev->policy->cpu);
+
+ return 0;
+}
/* Bind cpufreq callbacks to thermal cooling device ops */
static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
- .get_max_state = cpufreq_get_max_state,
- .get_cur_state = cpufreq_get_cur_state,
- .set_cur_state = cpufreq_set_cur_state,
-};
-
-static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
.get_max_state = cpufreq_get_max_state,
.get_cur_state = cpufreq_get_cur_state,
.set_cur_state = cpufreq_set_cur_state,
+#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
.get_requested_power = cpufreq_get_requested_power,
.state2power = cpufreq_state2power,
.power2state = cpufreq_power2state,
+#endif
};
/* Notifier for cpufreq policy change */
@@ -674,17 +672,16 @@ __cpufreq_cooling_register(struct device_node *np,
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
+#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR
if (capacitance) {
ret = update_freq_table(cpufreq_cdev, capacitance);
if (ret) {
cdev = ERR_PTR(ret);
goto remove_ida;
}
-
- cooling_ops = &cpufreq_power_cooling_ops;
- } else {
- cooling_ops = &cpufreq_cooling_ops;
}
+#endif
+ cooling_ops = &cpufreq_cooling_ops;
cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
cooling_ops);