[PATCH 4.14 004/115] hwmon: (pwm-fan) Disable PWM if fetching cooling data fails
From: Greg Kroah-Hartman
Date: Wed May 15 2019 - 07:17:44 EST
From: Stefan Wahren <stefan.wahren@xxxxxxxx>
commit 53f1647da3e8fb3e89066798f0fdc045064d353d upstream.
In case pwm_fan_of_get_cooling_data() fails we should disable the PWM
just like in the other error cases.
Fixes: 2e5219c77183 ("hwmon: (pwm-fan) Read PWM FAN configuration from device tree")
Cc: <stable@xxxxxxxxxxxxxxx> # 4.14+
Reported-by: Guenter Rock <linux@xxxxxxxxxxxx>
Signed-off-by: Stefan Wahren <stefan.wahren@xxxxxxxx>
Signed-off-by: Guenter Roeck <linux@xxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/hwmon/pwm-fan.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/hwmon/pwm-fan.c
+++ b/drivers/hwmon/pwm-fan.c
@@ -250,7 +250,7 @@ static int pwm_fan_probe(struct platform
ret = pwm_fan_of_get_cooling_data(&pdev->dev, ctx);
if (ret)
- return ret;
+ goto err_pwm_disable;
ctx->pwm_fan_state = ctx->pwm_fan_max_state;
if (IS_ENABLED(CONFIG_THERMAL)) {