[PATCH 5.1 30/85] iio: adc: modify NPCM ADC read reference voltage

From: Greg Kroah-Hartman
Date: Fri Jun 07 2019 - 11:54:11 EST


From: Tomer Maimon <tmaimon77@xxxxxxxxx>

commit 4e63ed6b90803eeb400c392e9ff493200d926b06 upstream.

Checking if regulator is valid before reading
NPCM ADC regulator voltage to avoid system crash
in a case the regulator is not valid.

Signed-off-by: Tomer Maimon <tmaimon77@xxxxxxxxx>
Cc: <Stable@xxxxxxxxxxxxxxx>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/iio/adc/npcm_adc.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

--- a/drivers/iio/adc/npcm_adc.c
+++ b/drivers/iio/adc/npcm_adc.c
@@ -149,7 +149,7 @@ static int npcm_adc_read_raw(struct iio_
}
return IIO_VAL_INT;
case IIO_CHAN_INFO_SCALE:
- if (info->vref) {
+ if (!IS_ERR(info->vref)) {
vref_uv = regulator_get_voltage(info->vref);
*val = vref_uv / 1000;
} else {