[PATCH v3 3/8] clocksource/drivers/tegra: Set and use timer's period
From: Dmitry Osipenko
Date: Tue Jun 18 2019 - 10:10:10 EST
The of_clk structure has a period field that is set up initially by
timer_of_clk_init(), that period value need to be adjusted for a case of
TIMER1-9 that are running at a fixed rate that doesn't match the clock's
rate. Note that the period value is currently used only by some of the
clocksource drivers internally and hence this is just a minor cleanup
change that doesn't fix anything.
Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx>
---
drivers/clocksource/timer-tegra.c | 5 +++--
1 file changed, 3 insertions(+), 2 deletions(-)
diff --git a/drivers/clocksource/timer-tegra.c b/drivers/clocksource/timer-tegra.c
index ff5a4ccb5d52..e6221e070499 100644
--- a/drivers/clocksource/timer-tegra.c
+++ b/drivers/clocksource/timer-tegra.c
@@ -71,9 +71,9 @@ static int tegra_timer_shutdown(struct clock_event_device *evt)
static int tegra_timer_set_periodic(struct clock_event_device *evt)
{
void __iomem *reg_base = timer_of_base(to_timer_of(evt));
+ unsigned long period = timer_of_period(to_timer_of(evt));
- writel_relaxed(TIMER_PTV_EN | TIMER_PTV_PER |
- ((timer_of_rate(to_timer_of(evt)) / HZ) - 1),
+ writel_relaxed(TIMER_PTV_EN | TIMER_PTV_PER | (period - 1),
reg_base + TIMER_PTV);
return 0;
@@ -297,6 +297,7 @@ static int __init tegra_init_timer(struct device_node *np, bool tegra20,
cpu_to->clkevt.rating = rating;
cpu_to->clkevt.cpumask = cpumask_of(cpu);
cpu_to->of_base.base = timer_reg_base + base;
+ cpu_to->of_clk.period = rate / HZ;
cpu_to->of_clk.rate = rate;
irq_set_status_flags(cpu_to->clkevt.irq, IRQ_NOAUTOEN);
--
2.22.0