[PATCH V14 11/13] dt-bindings: PHY: P2U: Add Tegra194 P2U block

From: Vidya Sagar
Date: Wed Jul 24 2019 - 13:49:51 EST


Add support for Tegra194 P2U (PIPE to UPHY) module block which is a glue
module instantiated one for each PCIe lane between Synopsys DesignWare core
based PCIe IP and Universal PHY block.

Signed-off-by: Vidya Sagar <vidyas@xxxxxxxxxx>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
Acked-by: Thierry Reding <treding@xxxxxxxxxx>
Acked-by: Kishon Vijay Abraham I <kishon@xxxxxx>
---
V14:
* None

V13:
* None

V12:
* None

V11:
* None

V10:
* None

V9:
* None

V8:
* None

V7:
* None

V6:
* Added Sob
* Changed node name from "p2u@xxxxxxxx" to "phy@xxxxxxxx"

V5:
* None

V4:
* None

V3:
* Changed node label to reflect new format that includes either 'hsio' or
'nvhs' in its name to reflect which UPHY brick they belong to

V2:
* This is a new patch in v2 series

.../bindings/phy/phy-tegra194-p2u.txt | 28 +++++++++++++++++++
1 file changed, 28 insertions(+)
create mode 100644 Documentation/devicetree/bindings/phy/phy-tegra194-p2u.txt

diff --git a/Documentation/devicetree/bindings/phy/phy-tegra194-p2u.txt b/Documentation/devicetree/bindings/phy/phy-tegra194-p2u.txt
new file mode 100644
index 000000000000..d23ff90baad5
--- /dev/null
+++ b/Documentation/devicetree/bindings/phy/phy-tegra194-p2u.txt
@@ -0,0 +1,28 @@
+NVIDIA Tegra194 P2U binding
+
+Tegra194 has two PHY bricks namely HSIO (High Speed IO) and NVHS (NVIDIA High
+Speed) each interfacing with 12 and 8 P2U instances respectively.
+A P2U instance is a glue logic between Synopsys DesignWare Core PCIe IP's PIPE
+interface and PHY of HSIO/NVHS bricks. Each P2U instance represents one PCIe
+lane.
+
+Required properties:
+- compatible: For Tegra19x, must contain "nvidia,tegra194-p2u".
+- reg: Should be the physical address space and length of respective each P2U
+ instance.
+- reg-names: Must include the entry "ctl".
+
+Required properties for PHY port node:
+- #phy-cells: Defined by generic PHY bindings. Must be 0.
+
+Refer to phy/phy-bindings.txt for the generic PHY binding properties.
+
+Example:
+
+p2u_hsio_0: phy@3e10000 {
+ compatible = "nvidia,tegra194-p2u";
+ reg = <0x03e10000 0x10000>;
+ reg-names = "ctl";
+
+ #phy-cells = <0>;
+};
--
2.17.1