Re: [PATCH net-next v7 3/3] net: phy: broadcom: add 1000Base-X support for BCM54616S
From: Florian Fainelli
Date: Thu Aug 15 2019 - 19:36:55 EST
On 8/11/19 4:40 PM, Tao Ren wrote:
> The BCM54616S PHY cannot work properly in RGMII->1000Base-X mode, mainly
> because genphy functions are designed for copper links, and 1000Base-X
> (clause 37) auto negotiation needs to be handled differently.
>
> This patch enables 1000Base-X support for BCM54616S by customizing 3
> driver callbacks, and it's verified to be working on Facebook CMM BMC
> platform (RGMII->1000Base-KX):
>
> - probe: probe callback detects PHY's operation mode based on
> INTERF_SEL[1:0] pins and 1000X/100FX selection bit in SerDES 100-FX
> Control register.
>
> - config_aneg: calls genphy_c37_config_aneg when the PHY is running in
> 1000Base-X mode; otherwise, genphy_config_aneg will be called.
>
> - read_status: calls genphy_c37_read_status when the PHY is running in
> 1000Base-X mode; otherwise, genphy_read_status will be called.
>
> Note: BCM54616S PHY can also be configured in RGMII->100Base-FX mode, and
> 100Base-FX support is not available as of now.
>
> Signed-off-by: Tao Ren <taoren@xxxxxx>
> - reg = bcm_phy_read_shadow(phydev, BCM5482_SHD_MODE);
> - bcm_phy_write_shadow(phydev, BCM5482_SHD_MODE,
> - reg | BCM5482_SHD_MODE_1000BX);
> + reg = bcm_phy_read_shadow(phydev, BCM54XX_SHD_MODE);
> + bcm_phy_write_shadow(phydev, BCM54XX_SHD_MODE,
> + reg | BCM54XX_SHD_MODE_1000BX);
This could have been a separate patch, but this looks reasonable to me
and this is correct with the datasheet, thanks Tao.
Reviewed-by: Florian Fainelli <f.fainelli@xxxxxxxxx>
--
Florian