On Tue, Aug 20, 2019 at 04:56:02PM +0300, Andy Shevchenko wrote:
On Tue, Aug 20, 2019 at 06:31:33PM +0800, Ramuthevar,Vadivel MuruganX wrote:It should be DR_TY_SHIFT(6) now since I dropped the negation.
+#define DR_TY_50OHM(x) ((~(x) << 28) & DR_TY_MASK)For consistency it should be
#define DR_TY_SHIFT(x) (((x) << 28) & DR_TY_MASK)
with explanation about 50 Ohm in the code below.
+ /* Drive impedance: 50 Ohm */Nice, you have already a comment here. Just use DR_TY_SHIFT(1)