[PATCH 4.19 58/85] iio: adc: max9611: Fix temperature reading in probe
From: Greg Kroah-Hartman
Date: Thu Aug 22 2019 - 13:28:36 EST
From: Jacopo Mondi <jacopo+renesas@xxxxxxxxxx>
commit b9ddd5091160793ee9fac10da765cf3f53d2aaf0 upstream.
The max9611 driver reads the die temperature at probe time to validate
the communication channel. Use the actual read value to perform the test
instead of the read function return value, which was mistakenly used so
far.
The temperature reading test was only successful because the 0 return
value is in the range of supported temperatures.
Fixes: 69780a3bbc0b ("iio: adc: Add Maxim max9611 ADC driver")
Signed-off-by: Jacopo Mondi <jacopo+renesas@xxxxxxxxxx>
Cc: <Stable@xxxxxxxxxxxxxxx>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/iio/adc/max9611.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/iio/adc/max9611.c
+++ b/drivers/iio/adc/max9611.c
@@ -483,7 +483,7 @@ static int max9611_init(struct max9611_d
if (ret)
return ret;
- regval = ret & MAX9611_TEMP_MASK;
+ regval &= MAX9611_TEMP_MASK;
if ((regval > MAX9611_TEMP_MAX_POS &&
regval < MAX9611_TEMP_MIN_NEG) ||