[PATCH] drm/meson: vclk: use the correct G12A frac max value
From: Neil Armstrong
Date: Mon Aug 26 2019 - 10:46:55 EST
When calculating the HDMI PLL settings for a DMT mode PHY frequency,
use the correct max fractional PLL value for G12A VPU.
With this fix, we can finally setup the 1024x76-60 mode.
Fixes: 202b9808f8ed ("drm/meson: Add G12A Video Clock setup")
Signed-off-by: Neil Armstrong <narmstrong@xxxxxxxxxxxx>
---
drivers/gpu/drm/meson/meson_vclk.c | 9 +++++++--
1 file changed, 7 insertions(+), 2 deletions(-)
diff --git a/drivers/gpu/drm/meson/meson_vclk.c b/drivers/gpu/drm/meson/meson_vclk.c
index ac491a781952..f690793ae2d5 100644
--- a/drivers/gpu/drm/meson/meson_vclk.c
+++ b/drivers/gpu/drm/meson/meson_vclk.c
@@ -638,13 +638,18 @@ static bool meson_hdmi_pll_validate_params(struct meson_drm *priv,
if (frac >= HDMI_FRAC_MAX_GXBB)
return false;
} else if (meson_vpu_is_compatible(priv, VPU_COMPATIBLE_GXM) ||
- meson_vpu_is_compatible(priv, VPU_COMPATIBLE_GXL) ||
- meson_vpu_is_compatible(priv, VPU_COMPATIBLE_G12A)) {
+ meson_vpu_is_compatible(priv, VPU_COMPATIBLE_GXL)) {
/* Empiric supported min/max dividers */
if (m < 106 || m > 247)
return false;
if (frac >= HDMI_FRAC_MAX_GXL)
return false;
+ } else if (meson_vpu_is_compatible(priv, VPU_COMPATIBLE_G12A)) {
+ /* Empiric supported min/max dividers */
+ if (m < 106 || m > 247)
+ return false;
+ if (frac >= HDMI_FRAC_MAX_G12A)
+ return false;
}
return true;
--