Re: [PATCH v3 04/14] arm64: dts: renesas: r8a7795: Add CMM units
From: Laurent Pinchart
Date: Mon Aug 26 2019 - 18:45:20 EST
Hi Jacopo,
Thank you for the patch.
On Sun, Aug 25, 2019 at 03:51:44PM +0200, Jacopo Mondi wrote:
> Add CMM units to Renesas R-Car H3 device tree and reference them from
> the Display Unit they are connected to.
>
> While at it, re-sort the du device node properties to match the ordering
> found in other SoCs.
>
> Signed-off-by: Jacopo Mondi <jacopo+renesas@xxxxxxxxxx>
Apart from the issue with compatible string as pointed out for patch
03/14,
Reviewed-by: Laurent Pinchart <laurent.pinchart@xxxxxxxxxxxxxxxx>
> ---
> arch/arm64/boot/dts/renesas/r8a7795.dtsi | 36 +++++++++++++++++++++++-
> 1 file changed, 35 insertions(+), 1 deletion(-)
>
> diff --git a/arch/arm64/boot/dts/renesas/r8a7795.dtsi b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> index 95deff66eeb6..21b4069f07e7 100644
> --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi
> @@ -2909,6 +2909,38 @@
> iommus = <&ipmmu_vi1 10>;
> };
>
> + cmm0: cmm@fea40000 {
> + compatible = "renesas,cmm-r8a7795";
> + reg = <0 0xfea40000 0 0x1000>;
> + clocks = <&cpg CPG_MOD 711>;
> + power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> + resets = <&cpg 711>;
> + };
> +
> + cmm1: cmm@fea50000 {
> + compatible = "renesas,cmm-r8a7795";
> + reg = <0 0xfea50000 0 0x1000>;
> + clocks = <&cpg CPG_MOD 710>;
> + power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> + resets = <&cpg 710>;
> + };
> +
> + cmm2: cmm@fea60000 {
> + compatible = "renesas,cmm-r8a7795";
> + reg = <0 0xfea60000 0 0x1000>;
> + clocks = <&cpg CPG_MOD 709>;
> + power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> + resets = <&cpg 709>;
> + };
> +
> + cmm3: cmm@fea70000 {
> + compatible = "renesas,cmm-r8a7795";
> + reg = <0 0xfea70000 0 0x1000>;
> + clocks = <&cpg CPG_MOD 708>;
> + power-domains = <&sysc R8A7795_PD_ALWAYS_ON>;
> + resets = <&cpg 708>;
> + };
> +
> csi20: csi2@fea80000 {
> compatible = "renesas,r8a7795-csi2";
> reg = <0 0xfea80000 0 0x10000>;
> @@ -3112,9 +3144,11 @@
> <&cpg CPG_MOD 722>,
> <&cpg CPG_MOD 721>;
> clock-names = "du.0", "du.1", "du.2", "du.3";
> - vsps = <&vspd0 0>, <&vspd1 0>, <&vspd2 0>, <&vspd0 1>;
> status = "disabled";
>
> + vsps = <&vspd0 0>, <&vspd1 0>, <&vspd2 0>, <&vspd0 1>;
> + cmms = <&cmm0 &cmm1 &cmm2 &cmm3>;
> +
> ports {
> #address-cells = <1>;
> #size-cells = <0>;
--
Regards,
Laurent Pinchart