[PATCH v2] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
From: Jan Kiszka
Date: Wed Sep 04 2019 - 02:42:40 EST
From: Jan Kiszka <jan.kiszka@xxxxxxxxxxx>
The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@xxxxxxxxxxx>
---
Changes in v2:
- fixed cut-off subject line (local tooling bug...)
Should go into stable as well, down to 4.19.
drivers/platform/x86/pmc_atom.c | 7 +++++++
1 file changed, 7 insertions(+)
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index aa53648a2214..9aca5e7ce6d0 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
+ {
+ .ident = "SIMATIC IPC227E",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+ },
+ },
{ /*sentinel*/ }
};
--
2.16.4
--
Siemens AG, Corporate Technology, CT RDA IOT SES-DE
Corporate Competence Center Embedded Linux