[PATCH] leds: pca963x: Fix open-drain initialization
From: Zahari Petkov
Date: Mon Oct 14 2019 - 08:36:16 EST
OUTDRV setting (bit 2) of Mode register 2 has a default value of 1.
During initialization when open-drain is used, instead of setting
OUTDRV to 0, the driver keeps it as 1. OUTDRV setting is now correctly
initialized to 0 when open-drain is used.
Additionally the BIT macro is used for improved readibility.
Fixes: bb29b9cccd95 ("leds: pca963x: Add bindings to invert polarity")
Signed-off-by: Zahari Petkov <zahari@xxxxxxxxx>
---
drivers/leds/leds-pca963x.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/drivers/leds/leds-pca963x.c b/drivers/leds/leds-pca963x.c
index 4afc317901a8..e3da2156b385 100644
--- a/drivers/leds/leds-pca963x.c
+++ b/drivers/leds/leds-pca963x.c
@@ -438,12 +438,12 @@ static int pca963x_probe(struct i2c_client *client,
PCA963X_MODE2);
/* Configure output: open-drain or totem pole (push-pull) */
if (pdata->outdrv == PCA963X_OPEN_DRAIN)
- mode2 |= 0x01;
+ mode2 &= ~BIT(2);
else
- mode2 |= 0x05;
+ mode2 |= BIT(2);
/* Configure direction: normal or inverted */
if (pdata->dir == PCA963X_INVERTED)
- mode2 |= 0x10;
+ mode2 |= BIT(4);
i2c_smbus_write_byte_data(pca963x->chip->client, PCA963X_MODE2,
mode2);
}
--
2.23.0