Re: [PATCH] platform/x86: huawei-wmi: make validation stricter in huawei_wmi_battery_set()
From: ayman . bagabas
Date: Tue Oct 15 2019 - 09:20:51 EST
On Tue, 2019-10-15 at 15:46 +0300, Dan Carpenter wrote:
> On Tue, Oct 15, 2019 at 08:21:59AM -0400, Ayman Bagabas wrote:
> > Hi Dan
> >
> > On Tue, Oct 15, 2019, 4:39 AM Dan Carpenter <
> > dan.carpenter@xxxxxxxxxx>
> > wrote:
> >
> > > I don't think it makes sense for "end" to be negative or for even
> > > for it
> > > to be less than "start". That also means that "start" can't be
> > > more
> > > than 100 which is good.
> > >
> >
> > While this makes sense, you run into issues where you cannot set
> > "start"
> > before "end" and vice versa.
> >
> > Take this scenario, you have start=70 and end=90, now you want to
> > set these
> > to start=40 and end=60, you would have to set "start" first before
> > you can
> > change the value of "end" otherwise you will run into EINVAL. Now
> > imagine
> > you wanna go the opposite direction, you would have to set "end"
> > before you
> > can change "start".
> > I think having a little wiggle room is fine for such scenarios.
> >
>
> I haven't tested this code... What you're describing sounds really
> very weird to me, but I will accept that you know more about your
> use cases than I do.
>
> My other concern is that right now you can set start > 100 or end <
> 0.
We should check for these cases.
>
> regards,
> dan carpenter
>