Re: [PATCH v3 1/5] net: ag71xx: port to phylink

From: Oleksij Rempel
Date: Tue Oct 22 2019 - 01:12:32 EST




On 22.10.19 00:21, Russell King - ARM Linux admin wrote:
On Mon, Oct 21, 2019 at 07:38:07AM +0200, Oleksij Rempel wrote:
+static void ag71xx_mac_validate(struct phylink_config *config,
+ unsigned long *supported,
+ struct phylink_link_state *state)
{
- struct ag71xx *ag = netdev_priv(ndev);
+ __ETHTOOL_DECLARE_LINK_MODE_MASK(mask) = { 0, };
+
+ if (state->interface != PHY_INTERFACE_MODE_NA &&
+ state->interface != PHY_INTERFACE_MODE_GMII &&
+ state->interface != PHY_INTERFACE_MODE_MII) {
+ bitmap_zero(supported, __ETHTOOL_LINK_MODE_MASK_NBITS);
+ return;
+ }
+
+ phylink_set(mask, MII);
+
+ /* flow control is not supported */
+
+ phylink_set(mask, 10baseT_Half);
+ phylink_set(mask, 10baseT_Full);
+ phylink_set(mask, 100baseT_Half);
+ phylink_set(mask, 100baseT_Full);
- ag71xx_link_adjust(ag, true);
+ if (state->interface == PHY_INTERFACE_MODE_NA &&
+ state->interface == PHY_INTERFACE_MODE_GMII) {

This is always false.

... I shame to myself :(

Apart from that, from just reading the patch I have no further concerns.

ok. thx!

Kind regards,
Oleksij Rempel

--
Pengutronix e.K. | |
Industrial Linux Solutions | http://www.pengutronix.de/ |
Peiner Str. 6-8, 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |