Re: [PATCH v3 2/9] KEYS: Defined functions to queue and dequeue keys for measurement

From: Mimi Zohar
Date: Thu Oct 31 2019 - 08:10:58 EST


On Wed, 2019-10-30 at 18:19 -0700, Lakshmi Ramasubramanian wrote:
> Key measurements cannot be done if the IMA hook to measure keys is
> called before IMA is initialized. Key measurement needs to be deferred
> if IMA is not yet initialized. Queued keys need to be processed when
> IMA initialization is completed.
>
> This patch defines functions to queue and de-queue keys for measurement.

I would defer this patch until later in the patch set, after having
the basic measuring of keys in place.