[PATCH 4.14 54/62] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table

From: Greg Kroah-Hartman
Date: Fri Nov 08 2019 - 14:00:29 EST


From: Jan Kiszka <jan.kiszka@xxxxxxxxxxx>

commit ad0d315b4d4e7138f43acf03308192ec00e9614d upstream.

The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@xxxxxxxxxxx>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/platform/x86/pmc_atom.c | 7 +++++++
1 file changed, 7 insertions(+)

--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -475,6 +475,13 @@ static const struct dmi_system_id critcl
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
+ {
+ .ident = "SIMATIC IPC227E",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+ },
+ },
{ /*sentinel*/ }
};