[PATCH AUTOSEL 4.19 089/209] media: rc: ir-rc6-decoder: enable toggle bit for Kathrein RCU-676 remote
From: Sasha Levin
Date: Tue Nov 12 2019 - 21:23:18 EST
From: Matthias Reichl <hias@xxxxxxxxx>
[ Upstream commit 85e4af0a7ae2f146769b7475ae531bf8a3f3afb4 ]
The Kathrein RCU-676 remote uses the 32-bit rc6 protocol and toggles
bit 15 (0x8000) on repeated button presses, like MCE remotes.
Add it's customer code 0x80460000 to the 32-bit rc6 toggle
handling code to get proper scancodes and toggle reports.
Signed-off-by: Matthias Reichl <hias@xxxxxxxxx>
Signed-off-by: Sean Young <sean@xxxxxxxx>
Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@xxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/media/rc/ir-rc6-decoder.c | 9 +++++++--
1 file changed, 7 insertions(+), 2 deletions(-)
diff --git a/drivers/media/rc/ir-rc6-decoder.c b/drivers/media/rc/ir-rc6-decoder.c
index 68487ce9f79b6..d96aed1343e42 100644
--- a/drivers/media/rc/ir-rc6-decoder.c
+++ b/drivers/media/rc/ir-rc6-decoder.c
@@ -40,6 +40,7 @@
#define RC6_6A_MCE_TOGGLE_MASK 0x8000 /* for the body bits */
#define RC6_6A_LCC_MASK 0xffff0000 /* RC6-6A-32 long customer code mask */
#define RC6_6A_MCE_CC 0x800f0000 /* MCE customer code */
+#define RC6_6A_KATHREIN_CC 0x80460000 /* Kathrein RCU-676 customer code */
#ifndef CHAR_BIT
#define CHAR_BIT 8 /* Normally in <limits.h> */
#endif
@@ -242,13 +243,17 @@ static int ir_rc6_decode(struct rc_dev *dev, struct ir_raw_event ev)
toggle = 0;
break;
case 32:
- if ((scancode & RC6_6A_LCC_MASK) == RC6_6A_MCE_CC) {
+ switch (scancode & RC6_6A_LCC_MASK) {
+ case RC6_6A_MCE_CC:
+ case RC6_6A_KATHREIN_CC:
protocol = RC_PROTO_RC6_MCE;
toggle = !!(scancode & RC6_6A_MCE_TOGGLE_MASK);
scancode &= ~RC6_6A_MCE_TOGGLE_MASK;
- } else {
+ break;
+ default:
protocol = RC_PROTO_RC6_6A_32;
toggle = 0;
+ break;
}
break;
default:
--
2.20.1