[PATCH v2 09/11] thermal: tegra: Appease the kernel-doc deity

From: Amit Kucheria
Date: Wed Nov 20 2019 - 10:46:26 EST


Fix up the following warning when compiled with make W=1:

linux.git/drivers/thermal/tegra/soctherm.c:369: warning: Function parameter or member 'value' not described in 'ccroc_writel'
linux.git/drivers/thermal/tegra/soctherm.c:369: warning: Excess function parameter 'v' description in 'ccroc_writel'
linux.git/drivers/thermal/tegra/soctherm.c:447: warning: Function parameter or member 'dev' not described in 'enforce_temp_range'
linux.git/drivers/thermal/tegra/soctherm.c:772: warning: Function parameter or member 'sg' not described in 'tegra_soctherm_set_hwtrips'
linux.git/drivers/thermal/tegra/soctherm.c:772: warning: Function parameter or member 'tz' not described in 'tegra_soctherm_set_hwtrips'
linux.git/drivers/thermal/tegra/soctherm.c:944: warning: Function parameter or member 'ts' not described in 'soctherm_oc_intr_enable'
linux.git/drivers/thermal/tegra/soctherm.c:1167: warning: Function parameter or member 'data' not described in 'soctherm_oc_irq_disable'
linux.git/drivers/thermal/tegra/soctherm.c:1167: warning: Excess function parameter 'irq_data' description in 'soctherm_oc_irq_disable'
linux.git/drivers/thermal/tegra/soctherm.c:1224: warning: Function parameter or member 'ctrlr' not described in 'soctherm_irq_domain_xlate_twocell'
linux.git/drivers/thermal/tegra/soctherm.c:1686: warning: Function parameter or member 'pdev' not described in 'soctherm_init_hw_throt_cdev'
linux.git/drivers/thermal/tegra/soctherm.c:1764: warning: Function parameter or member 'ts' not described in 'throttlectl_cpu_level_cfg'
linux.git/drivers/thermal/tegra/soctherm.c:1812: warning: Function parameter or member 'ts' not described in 'throttlectl_cpu_level_select'
linux.git/drivers/thermal/tegra/soctherm.c:1855: warning: Function parameter or member 'ts' not described in 'throttlectl_cpu_mn'
linux.git/drivers/thermal/tegra/soctherm.c:1886: warning: Function parameter or member 'ts' not described in 'throttlectl_gpu_level_select'
linux.git/drivers/thermal/tegra/soctherm.c:1928: warning: Function parameter or member 'ts' not described in 'soctherm_throttle_program'

Signed-off-by: Amit Kucheria <amit.kucheria@xxxxxxxxxx>
Reviewed-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx>
---
drivers/thermal/tegra/soctherm.c | 15 +++++++++++++--
1 file changed, 13 insertions(+), 2 deletions(-)

diff --git a/drivers/thermal/tegra/soctherm.c b/drivers/thermal/tegra/soctherm.c
index 5acaad3a594f..66e0639da4bf 100644
--- a/drivers/thermal/tegra/soctherm.c
+++ b/drivers/thermal/tegra/soctherm.c
@@ -360,7 +360,7 @@ static struct soctherm_oc_irq_chip_data soc_irq_cdata;
/**
* ccroc_writel() - writes a value to a CCROC register
* @ts: pointer to a struct tegra_soctherm
- * @v: the value to write
+ * @value: the value to write
* @reg: the register offset
*
* Writes @v to @reg. No return value.
@@ -435,6 +435,7 @@ static int tegra_thermctl_get_temp(void *data, int *out_temp)

/**
* enforce_temp_range() - check and enforce temperature range [min, max]
+ * @dev: struct device * of the SOC_THERM instance
* @trip_temp: the trip temperature to check
*
* Checks and enforces the permitted temperature range that SOC_THERM
@@ -747,6 +748,8 @@ static int get_hot_temp(struct thermal_zone_device *tz, int *trip, int *temp)
/**
* tegra_soctherm_set_hwtrips() - set HW trip point from DT data
* @dev: struct device * of the SOC_THERM instance
+ * @sg: pointer to the sensor group to set the thermtrip temperature for
+ * @tz: struct thermal_zone_device *
*
* Configure the SOC_THERM HW trip points, setting "THERMTRIP"
* "THROTTLE" trip points , using "thermtrips", "critical" or "hot"
@@ -931,6 +934,7 @@ static irqreturn_t soctherm_thermal_isr_thread(int irq, void *dev_id)

/**
* soctherm_oc_intr_enable() - Enables the soctherm over-current interrupt
+ * @ts: pointer to a struct tegra_soctherm
* @alarm: The soctherm throttle id
* @enable: Flag indicating enable the soctherm over-current
* interrupt or disable it
@@ -1156,7 +1160,7 @@ static void soctherm_oc_irq_enable(struct irq_data *data)

/**
* soctherm_oc_irq_disable() - Disables overcurrent interrupt requests
- * @irq_data: The interrupt request information
+ * @data: The interrupt request information
*
* Clears the interrupt request enable bit of the overcurrent
* interrupt request chip data.
@@ -1206,6 +1210,7 @@ static int soctherm_oc_irq_map(struct irq_domain *h, unsigned int virq,
/**
* soctherm_irq_domain_xlate_twocell() - xlate for soctherm interrupts
* @d: Interrupt request domain
+ * @ctrlr: Controller device tree node
* @intspec: Array of u32s from DTs "interrupt" property
* @intsize: Number of values inside the intspec array
* @out_hwirq: HW IRQ value associated with this interrupt
@@ -1681,6 +1686,7 @@ static int soctherm_throt_cfg_parse(struct device *dev,
/**
* soctherm_init_hw_throt_cdev() - Parse the HW throttle configurations
* and register them as cooling devices.
+ * @pdev: Pointer to platform_device struct
*/
static void soctherm_init_hw_throt_cdev(struct platform_device *pdev)
{
@@ -1751,6 +1757,7 @@ static void soctherm_init_hw_throt_cdev(struct platform_device *pdev)

/**
* throttlectl_cpu_level_cfg() - programs CCROC NV_THERM level config
+ * @ts: pointer to a struct tegra_soctherm
* @level: describing the level LOW/MED/HIGH of throttling
*
* It's necessary to set up the CPU-local CCROC NV_THERM instance with
@@ -1798,6 +1805,7 @@ static void throttlectl_cpu_level_cfg(struct tegra_soctherm *ts, int level)

/**
* throttlectl_cpu_level_select() - program CPU pulse skipper config
+ * @ts: pointer to a struct tegra_soctherm
* @throt: the LIGHT/HEAVY of throttle event id
*
* Pulse skippers are used to throttle clock frequencies. This
@@ -1841,6 +1849,7 @@ static void throttlectl_cpu_level_select(struct tegra_soctherm *ts,

/**
* throttlectl_cpu_mn() - program CPU pulse skipper configuration
+ * @ts: pointer to a struct tegra_soctherm
* @throt: the LIGHT/HEAVY of throttle event id
*
* Pulse skippers are used to throttle clock frequencies. This
@@ -1874,6 +1883,7 @@ static void throttlectl_cpu_mn(struct tegra_soctherm *ts,

/**
* throttlectl_gpu_level_select() - selects throttling level for GPU
+ * @ts: pointer to a struct tegra_soctherm
* @throt: the LIGHT/HEAVY of throttle event id
*
* This function programs soctherm's interface to GK20a NV_THERM to select
@@ -1918,6 +1928,7 @@ static int soctherm_oc_cfg_program(struct tegra_soctherm *ts,

/**
* soctherm_throttle_program() - programs pulse skippers' configuration
+ * @ts: pointer to a struct tegra_soctherm
* @throt: the LIGHT/HEAVY of the throttle event id.
*
* Pulse skippers are used to throttle clock frequencies.
--
2.20.1