[PATCH AUTOSEL 4.14 022/127] ubi: Do not drop UBI device reference before using
From: Sasha Levin
Date: Fri Nov 22 2019 - 00:56:17 EST
From: Pan Bian <bianpan2016@xxxxxxx>
[ Upstream commit e542087701f09418702673631a908429feb3eae0 ]
The UBI device reference is dropped but then the device is used as a
parameter of ubi_err. The bug is introduced in changing ubi_err's
behavior. The old ubi_err does not require a UBI device as its first
parameter, but the new one does.
Fixes: 32608703310 ("UBI: Extend UBI layer debug/messaging capabilities")
Signed-off-by: Pan Bian <bianpan2016@xxxxxxx>
Reviewed-by: Boris Brezillon <boris.brezillon@xxxxxxxxxxx>
Signed-off-by: Richard Weinberger <richard@xxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/mtd/ubi/kapi.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/mtd/ubi/kapi.c b/drivers/mtd/ubi/kapi.c
index d4b2e87444986..c2cf6bd3c162a 100644
--- a/drivers/mtd/ubi/kapi.c
+++ b/drivers/mtd/ubi/kapi.c
@@ -227,9 +227,9 @@ struct ubi_volume_desc *ubi_open_volume(int ubi_num, int vol_id, int mode)
out_free:
kfree(desc);
out_put_ubi:
- ubi_put_device(ubi);
ubi_err(ubi, "cannot open device %d, volume %d, error %d",
ubi_num, vol_id, err);
+ ubi_put_device(ubi);
return ERR_PTR(err);
}
EXPORT_SYMBOL_GPL(ubi_open_volume);
--
2.20.1