Re: [PATCH][next] scsi: pm80xx: fix logic to break out of loop when register value is 2 or 3

From: Jinpu Wang
Date: Fri Nov 22 2019 - 03:53:56 EST


On Wed, Nov 20, 2019 at 2:50 PM Colin King <colin.king@xxxxxxxxxxxxx> wrote:
>
> From: Colin Ian King <colin.king@xxxxxxxxxxxxx>
>
> The condition (reg_val != 2) || (reg_val != 3) will always be true because
> reg_val cannot be equal to two different values at the same time. Fix this
> by replacing the || operator with && so that the loop will loop if reg_val
> is not a 2 and not a 3 as was originally intended.
>
> Addresses-Coverity: ("Constant expression result")
> Fixes: 50dc2f221455 ("scsi: pm80xx: Modified the logic to collect fatal dump")
> Signed-off-by: Colin Ian King <colin.king@xxxxxxxxxxxxx>
looks fine. thanks Colin.
Acked-by: Jack Wang <jinpu.wang@xxxxxxxxxxxxxxx>
> ---
> drivers/scsi/pm8001/pm80xx_hwi.c | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)
>
> diff --git a/drivers/scsi/pm8001/pm80xx_hwi.c b/drivers/scsi/pm8001/pm80xx_hwi.c
> index 19601138e889..d41908b23760 100644
> --- a/drivers/scsi/pm8001/pm80xx_hwi.c
> +++ b/drivers/scsi/pm8001/pm80xx_hwi.c
> @@ -348,7 +348,7 @@ ssize_t pm80xx_get_fatal_dump(struct device *cdev,
> do {
> reg_val = pm8001_mr32(fatal_table_address,
> MPI_FATAL_EDUMP_TABLE_STATUS);
> - } while (((reg_val != 2) || (reg_val != 3)) &&
> + } while (((reg_val != 2) && (reg_val != 3)) &&
> time_before(jiffies, start));
>
> if (reg_val < 2) {
> --
> 2.24.0
>