[PATCH v3 1/5] dt-bindings: power: Introduce one property to describe the battery resistance with temperature changes
From: Baolin Wang
Date: Sun Dec 08 2019 - 22:57:23 EST
From: Baolin Wang <baolin.wang@xxxxxxxxxx>
Since the battery internal resistance can be changed as the temperature
changes, thus add one table to describe the battery resistance percent
in different temperatures to get a accurate battery internal resistance.
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>
Signed-off-by: Baolin Wang <baolin.wang@xxxxxxxxxx>
Signed-off-by: Baolin Wang <baolin.wang7@xxxxxxxxx>
---
.../devicetree/bindings/power/supply/battery.txt | 5 +++++
1 file changed, 5 insertions(+)
diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt
index 5c913d4c..3049cf8 100644
--- a/Documentation/devicetree/bindings/power/supply/battery.txt
+++ b/Documentation/devicetree/bindings/power/supply/battery.txt
@@ -35,6 +35,10 @@ Optional Properties:
for each of the battery capacity lookup table. The first temperature value
specifies the OCV table 0, and the second temperature value specifies the
OCV table 1, and so on.
+ - resistance-temp-table: An array providing the temperature in degree Celsius
+ and corresponding battery internal resistance percent, which is used to look
+ up the resistance percent according to current temperature to get a accurate
+ batterty internal resistance in different temperatures.
Battery properties are named, where possible, for the corresponding
elements in enum power_supply_property, defined in
@@ -61,6 +65,7 @@ Example:
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
+ resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
};
charger: charger@11 {
--
1.7.9.5