Re: [PATCH] regulator: max77650: add of_match table
From: Mark Brown
Date: Tue Dec 10 2019 - 08:02:49 EST
On Tue, Dec 10, 2019 at 01:51:38PM +0100, Bartosz Golaszewski wrote:
> wt., 10 gru 2019 o 13:12 Mark Brown <broonie@xxxxxxxxxx> napisaÅ(a):
> > Why would we need to use a compatible string in a child node to load the
> > regulator driver, surely we can just register a platform device in the
> > MFD?
> The device is registered all right from MFD code, but the module won't
> be loaded automatically from user-space even with the right
> MODULE_ALIAS() for sub-nodes unless we define the
> MODULE_DEVICE_TABLE().
This seems to work fine for other drivers and the platform bus has to be
usable on systems that don't use DT so that doesn't sound right. Which
MODULE_ALIAS() are you using exactly?
> Besides: the DT bindings define the compatible for sub-nodes already.
> We should probably conform to that.
I would say that's a mistake and should be fixed, this particular way of
loading the regulators is a Linux implementation detail.
Attachment:
signature.asc