[PATCH AUTOSEL 4.9 48/91] bnx2x: Fix PF-VF communication over multi-cos queues.
From: Sasha Levin
Date: Tue Dec 10 2019 - 17:31:47 EST
From: Manish Chopra <manishc@xxxxxxxxxxx>
[ Upstream commit dc5a3d79c345871439ffe72550b604fcde9770e1 ]
PF driver doesn't enable tx-switching for all cos queues/clients,
which causes packets drop from PF to VF. Fix this by enabling
tx-switching on all cos queues/clients.
Signed-off-by: Manish Chopra <manishc@xxxxxxxxxxx>
Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
.../net/ethernet/broadcom/bnx2x/bnx2x_sriov.c | 16 +++++++++++-----
1 file changed, 11 insertions(+), 5 deletions(-)
diff --git a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c
index c6e059119b22e..e8a09d0afe1c9 100644
--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_sriov.c
@@ -2376,15 +2376,21 @@ static int bnx2x_set_pf_tx_switching(struct bnx2x *bp, bool enable)
/* send the ramrod on all the queues of the PF */
for_each_eth_queue(bp, i) {
struct bnx2x_fastpath *fp = &bp->fp[i];
+ int tx_idx;
/* Set the appropriate Queue object */
q_params.q_obj = &bnx2x_sp_obj(bp, fp).q_obj;
- /* Update the Queue state */
- rc = bnx2x_queue_state_change(bp, &q_params);
- if (rc) {
- BNX2X_ERR("Failed to configure Tx switching\n");
- return rc;
+ for (tx_idx = FIRST_TX_COS_INDEX;
+ tx_idx < fp->max_cos; tx_idx++) {
+ q_params.params.update.cid_index = tx_idx;
+
+ /* Update the Queue state */
+ rc = bnx2x_queue_state_change(bp, &q_params);
+ if (rc) {
+ BNX2X_ERR("Failed to configure Tx switching\n");
+ return rc;
+ }
}
}
--
2.20.1