[PATCH 4.4 090/162] iio: humidity: hdc100x: fix IIO_HUMIDITYRELATIVE channel reporting
From: Greg Kroah-Hartman
Date: Thu Dec 19 2019 - 13:38:47 EST
From: Chris Lesiak <chris.lesiak@xxxxxxxxx>
commit 342a6928bd5017edbdae376042d8ad6af3d3b943 upstream.
The IIO_HUMIDITYRELATIVE channel was being incorrectly reported back
as percent when it should have been milli percent. This is via an
incorrect scale value being returned to userspace.
Signed-off-by: Chris Lesiak <chris.lesiak@xxxxxxxxx>
Acked-by: Matt Ranostay <matt.ranostay@xxxxxxxxxxxx>
Cc: <Stable@xxxxxxxxxxxxxxx>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/iio/humidity/hdc100x.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
--- a/drivers/iio/humidity/hdc100x.c
+++ b/drivers/iio/humidity/hdc100x.c
@@ -215,7 +215,7 @@ static int hdc100x_read_raw(struct iio_d
*val2 = 65536;
return IIO_VAL_FRACTIONAL;
} else {
- *val = 100;
+ *val = 100000;
*val2 = 65536;
return IIO_VAL_FRACTIONAL;
}