Re: [PATCH RESEND] phy: exynos5-usbdrd: Calibrating makes sense only for USB2.0 PHY
From: Marek Szyprowski
Date: Mon Jan 13 2020 - 09:02:10 EST
On 13.12.2019 09:31, Marek Szyprowski wrote:
> PHY calibration is needed only for USB2.0 (UTMI) PHY, so skip calling
> calibration code when phy_calibrate() is called for USB3.0 (PIPE3) PHY.
>
> Fixes: d8c80bb3b55b ("phy: exynos5-usbdrd: Calibrate LOS levels for exynos5420/5800")
> Signed-off-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx>
gentle ping
> ---
> drivers/phy/samsung/phy-exynos5-usbdrd.c | 4 +++-
> 1 file changed, 3 insertions(+), 1 deletion(-)
>
> diff --git a/drivers/phy/samsung/phy-exynos5-usbdrd.c b/drivers/phy/samsung/phy-exynos5-usbdrd.c
> index 646259bee909..f07edd80d2f3 100644
> --- a/drivers/phy/samsung/phy-exynos5-usbdrd.c
> +++ b/drivers/phy/samsung/phy-exynos5-usbdrd.c
> @@ -714,7 +714,9 @@ static int exynos5_usbdrd_phy_calibrate(struct phy *phy)
> struct phy_usb_instance *inst = phy_get_drvdata(phy);
> struct exynos5_usbdrd_phy *phy_drd = to_usbdrd_phy(inst);
>
> - return exynos5420_usbdrd_phy_calibrate(phy_drd);
> + if (inst->phy_cfg->id == EXYNOS5_DRDPHY_UTMI)
> + return exynos5420_usbdrd_phy_calibrate(phy_drd);
> + return 0;
> }
>
> static const struct phy_ops exynos5_usbdrd_phy_ops = {
Best regards
--
Marek Szyprowski, PhD
Samsung R&D Institute Poland