On 2/5/20 1:51 PM, Dan Murphy wrote:
HeinerWith your current link_change_notify function it would not be possible
On 2/5/20 3:16 PM, Heiner Kallweit wrote:
On 04.02.2020 19:13, Dan Murphy wrote:I just don't have a requirement from our customer to make it adjustable
Set the speed optimization bit on the DP83867 PHY.As stated in the first review, it would be appreciated if you implement
This feature can also be strapped on the 64 pin PHY devices
but the 48 pin devices do not have the strap pin available to enable
this feature in the hardware. PHY team suggests to have this bit set.
With this bit set the PHY will auto negotiate and report the link
parameters in the PHYSTS register. This register provides a single
location within the register set for quick access to commonly accessed
information.
In this case when auto negotiation is on the PHY core reads the bits
that have been configured or if auto negotiation is off the PHY core
reads the BMCR register and sets the phydev parameters accordingly.
This Giga bit PHY can throttle the speed to 100Mbps or 10Mbps to
accomodate a
4-wire cable. If this should occur the PHYSTS register contains the
current negotiated speed and duplex mode.
In overriding the genphy_read_status the dp83867_read_status will do a
genphy_read_status to setup the LP and pause bits. And then the PHYSTS
register is read and the phydev speed and duplex mode settings are
updated.
Signed-off-by: Dan Murphy <dmurphy@xxxxxx>
---
v2 - Updated read status to call genphy_read_status first, added
link_change
callback to notify of speed change and use phy_set_bits -
https://lore.kernel.org/patchwork/patch/1188348/
also the downshift tunable. This could be a separate patch in this
series.
Most of the implementation would be boilerplate code.
so I did not want to add something extra.
I can add in for v3.
And I have to admit that I'm not too happy with the term "speedAck. The data sheet actually says "Speed optimization, also known as
optimization".
This sounds like the PHY has some magic to establish a 1.2Gbps link.
Even though the vendor may call it this way in the datasheet, the
standard
term is "downshift". I'm fine with using "speed optimization" in
constants
to be in line with the datasheet. Just a comment in the code would be
helpful
that speed optimization is the vendor's term for downshift.
link downshift"
So I probably will just rename everything down shift.
I don't see a register that gives us that status drivers/net/phy/dp83867.c | 55 +++++++++++++++++++++++++++++++++++++++The link partner may simply not advertise 1Gbps. How do you know that
 1 file changed, 55 insertions(+)
diff --git a/drivers/net/phy/dp83867.c b/drivers/net/phy/dp83867.c
index 967f57ed0b65..6f86ca1ebb51 100644
--- a/drivers/net/phy/dp83867.c
+++ b/drivers/net/phy/dp83867.c
@@ -21,6 +21,7 @@
 #define DP83867_DEVADDR 0x1f
  #define MII_DP83867_PHYCTRL 0x10
+#define MII_DP83867_PHYSTSÂÂÂ 0x11
 #define MII_DP83867_MICR 0x12
 #define MII_DP83867_ISR 0x13
 #define DP83867_CFG2 0x14
@@ -118,6 +119,15 @@
 #define DP83867_IO_MUX_CFG_CLK_O_SEL_MASK (0x1f << 8)
 #define DP83867_IO_MUX_CFG_CLK_O_SEL_SHIFT 8
 +/* PHY STS bits */
+#define DP83867_PHYSTS_1000ÂÂÂÂÂÂÂÂÂÂÂ BIT(15)
+#define DP83867_PHYSTS_100ÂÂÂÂÂÂÂÂÂÂÂ BIT(14)
+#define DP83867_PHYSTS_DUPLEXÂÂÂÂÂÂÂÂÂÂÂ BIT(13)
+#define DP83867_PHYSTS_LINKÂÂÂÂÂÂÂÂÂÂÂ BIT(10)
+
+/* CFG2 bits */
+#define DP83867_SPEED_OPTIMIZED_ENÂÂÂÂÂÂÂ (BIT(8) | BIT(9))
+
 /* CFG3 bits */
 #define DP83867_CFG3_INT_OE BIT(7)
 #define DP83867_CFG3_ROBUST_AUTO_MDIX BIT(9)
@@ -287,6 +297,43 @@ static int dp83867_config_intr(struct phy_device
*phydev)
ÂÂÂÂÂ return phy_write(phydev, MII_DP83867_MICR, micr_status);
 }
 +static void dp83867_link_change_notify(struct phy_device *phydev)
+{
+ÂÂÂ if (phydev->state != PHY_RUNNING)
+ÂÂÂÂÂÂÂ return;
+
+ÂÂÂ if (phydev->speed == SPEED_100 || phydev->speed == SPEED_10)
+ÂÂÂÂÂÂÂ phydev_warn(phydev, "Downshift detected connection is
%iMbps\n",
+ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ phydev->speed);
a link speed of e.g. 100Mbps is caused by a downshift?
Some PHY's I've seen with this feature have a flag somewhere indicating
that downshift occurred. How about the PHY here?
I will ask the hardware team if there is one.
This is a 1Gbps PHY by default so if a slower connection is established
due to faulty cabling or LP advertisement then this would be a down
shift IMO.
to know whether the PHY was connected to a link partner that advertised
only 10/100 and so 100 ended up being the link speed, or the link
partner was capable of 10/100/1000 and downshift reduced the link speed.
If you cannot tell the difference from a register, it might be better to
simply omit that function then.