Re: [PATCH 1/6] spi: spi-fsl-dspi: Don't access reserved fields in SPI_MCR

From: Vladimir Oltean
Date: Mon Mar 09 2020 - 14:10:00 EST


On Mon, 9 Mar 2020 at 20:05, Michael Walle <michael@xxxxxxxx> wrote:
>
> Am 2020-03-09 15:56, schrieb Vladimir Oltean:
> > From: Vladimir Oltean <vladimir.oltean@xxxxxxx>
> >
> > The SPI_MCR_PCSIS macro assumes that the controller has a number of
> > chip
> > select signals equal to 6. That is not always the case, but actually is
> > described through the driver-specific " signals equal to 6. That is not
> > always the case, but actually is described through the driver-specific
> > "spi-num-chipselects" device tree binding.
>
> Repeated sentence? Was this your intention?
>

No, I must have tripped over my vim shortcuts. Sorry.

-Vladimir