On 3/11/20 6:35 AM, Srinivas Kandagatla wrote:
WSA881x works in PDM mode so the wordlength is fixed, which also makes
the only field "WordLength" in DPN_BlockCtrl1 register a read-only.
Writing to this register will throw up errors with Qualcomm Controller.
it'd be good to clarify the nature of these errors, i.e.
a) is this the Slave device responding with a NAK?
b) is this the Slave device responding with COMMAND_IGNORED, and those responses not handled by the controller?
c) something else?
Thanks!