Re: [RFC PATCH v4 8/8] arm64: tegra: Add Tegra VI CSI support in device tree
From: Dmitry Osipenko
Date: Sun Mar 15 2020 - 08:54:13 EST
15.03.2020 04:46, Sowjanya Komatineni ÐÐÑÐÑ:
> Tegra210 contains VI controller for video input capture from MIPI
> CSI camera sensors and also supports built-in test pattern generator.
>
> CSI ports can be one-to-one mapped to VI channels for capturing from
> an external sensor or from built-in test pattern generator.
>
> This patch adds support for VI and CSI and enables them in Tegra210
> device tree.
>
> Signed-off-by: Sowjanya Komatineni <skomatineni@xxxxxxxxxx>
> ---
Hello Sowjanya,
...
> +
> + pd_venc: venc {
> + clocks = <&tegra_car TEGRA210_CLK_VI>,
> + <&tegra_car TEGRA210_CLK_CSI>;
> + resets = <&tegra_car 20>,
What is the clock #20?
> + <&tegra_car TEGRA210_CLK_CSI>,
> + <&mc TEGRA210_MC_RESET_VI>;
Does this order means that memory controller will be reset *after*
resetting the CSI/VI hardware? This is incorrect reset sequence.
The memory controller reset should be kept asserted during of the time
of the hardware resetting procedure.
The correct sequence should be as follows:
1. Assert MC
2. Reset VI
3. Deassert MC